As Property Managers you have allot on your plate in fact often you are balancing many plates. I have written a guide for alarms systems just for Property Managers that will allow you to go right to the section that you have questions about.
(801) 898 6003 email is Larry.Love@JCI.com
If you have a building that needs to monitor the flow and tamper for the fire sprinkler system I can help you with that. If you need a security system for an empty building I can also help you with that.
Johnson Controls does Fire Alarm Testing
Johnson Controls does Fire Sprinkler Testing and Certification
Johnson Control does Fire Extinguisher testing and certification.
For pricing for any of the testing or monitoring contact Shandie.a.gorney@jci.com 801 801 214 5668 and she can get you pricing and the agreements. Pricing is very reasonable when compared with other companies.
ALARM SYSTEMS MADE EASY
A Practical guide to understanding alarm systems
By Larry Love Larry.Love@JCI.com Cell 801 898 6003
Since this was written a few years ago keep in mind that pricing and code changes so when you have concerns, corrections or questions contact me and I can help with any of those items.
Pricing listed is for examples only. Please get individual quotes on each project from Larry Love
Understand that as technology changes so does this information, codes get updated and things change.
Rather than reading the entire booklet just turn to the section you need.
Fire Alarm Systems –Zoned – Conventional 2
Fire Alarm Systems – Addressable – 2
Fire Alarm Systems – Analog Addressable – 3
Battery calculations and voltage line drops and why they are important -4
Elevator Recall/Monitoring (Fire alarm can recall elevator to floor without fire) -5
Communicators- DACT – Dialers – IP Internet – Radio – Cellular -6
Central Station -7
Customer Information sheet 8 then prices for monitoring options page 23
Mass Notification – Speaker Strobes / Voice Evacuation /Fire Phones -9
CCTV – Camera Systems – Analog / IP / DVRs / NVRs -10
Coax – Cable – Low voltage wire - A brief overview - 11
Access Control – 12
Security / Intrusion – 13
Partitions -14
Security Options not commonly understood- 14
Security Codes and understanding how they can/should be programmed-15
Electrical Engineer information and why it is important to talk to them-16
Code info such as NFPA 72, NFPA 70 (NEC) and Life safety 101 (ADA) & R710 --17
Maintenance note – extend the life of your system-18
Supplemental information 19-20
General Terms: 21
Monitoring – Pricing 23-
A typical zoned (Conventional ) fire alarm system will monitor a small building where just a few zones are needed such as monitoring if there is water flowing from the fire sprinkler system (FLOW ALARM) and whether or not the water valves have been turned off or tampered with (TAMPER). Typically you have at least one smoke detector and at least one pull station on a system such as this. This would be a 4 zone conventional panel and normally these smaller panels cost much less than a large expandable system. Horn/Strobes will normally be installed to warn the occupants to evacuate. Horn/Strobes are normally red although they can be white and they have fire written on the side and they make noise and flash. To install a zoned system the wire will be installed from each device back to the panel.
· Trouble shooting tips – If a sprinkler tamper valve is shut off or even turned partially it could set the supervisory signal off.
· When the dispatchers at the central station receive a supervisory signal such as a TAMPER they don’t dispatch the fire department they just call to inform you that the water may be shut off so you can correct the issue. If you cannot correct it yourself it is prudent to call for service since this is a liability issue if there is a fire and the system does not function.
· When a FLOW signal is received Fire Department is dispatched
Fire Alarm Systems – Addressable
An addressable panel will have one or more circuits where all the input devices are connected and the panel will be programmed to recognize each point individually and communicate this to the central station. This midrange option is normally slightly more money than a zoned system and a bit less than an analog addressable system. Normally addressable systems are required on buildings over one story. Up to 99 points on one circuit (set of wires) is the norm.
Fire Alarm – Analog Addressable
An analog addressable panel will report individual points just like the addressable system although it also can report additional information such as “how full of dirt the smokes are” which is the obscuration level and the heat detectors may even report the exact temperature and what room they are in. Many analog systems allow you to get a list of the sensitivity of each smoke detector. This allows your maintenance department to schedule which smokes need to be cleaned. Even analog addressable fire alarm systems have different levels of panels. If your building will never have over 127 points then you may not need the panel that can expand to 1500 points or higher.
Here at JCI Johnson Controls Fire Protection we have the ability to do very large networked systems as well. Voice Evacuation with speaker strobes, smoke control, area of refuge and more.
Johnson Controls installs Simplex Fire Alarm systems that have addressable horn strobes which is a very cool thing. Instead of having to bother the people in the building once a year we run a quick test on our addressable horn strobes and the panel gives us a report of all the problems with any strobes, horn strobes and speaker strobes.
Some devices and appliances that may be connected to your Fire Alarm
Manual Alarm boxes / Pull boxes / Pull stations (Should take two actions to activate)
Smoke detectors – 24 volt DC There are not batteries in these smokes –backup in panel
Heat detectors – resettable and non resettable many come with specific temperatures
Remote Annunciator – Keypad – These can notify you of exactly what the main panel sees
Duct Detectors monitor if there is smoke in the ducts and they can shut down the air handlers
Duct Detectors may have RTS remote test switches mounted in an accessible area.
*Many times the DD Duct Detectors are part of the RTU Roof Top Units although they will need a MM Monitor module
MM – Monitor modules or input modules can monitor almost any device
Output relays CM or R – These relays provide an output to activate equipment
PIV – Post indicator valve (Where you can turn off the water to the entire building)
Horn/Strobes – Strobe only units (typical for restrooms) – Speaker Strobes- (Warn to leave) - Strobes help those that are hearing impaired, Horns help those that are visually impaired
Door Holder magnets that hold doors open will release upon fire alarm dropping doors closed - This can help so the fire does not spread.
Tie in to specific dampers to stop air flow so smoke is not spread throughout the building
Smoke Control system allows you to move smoke from one area to another or vent it out
Flow – Fire Alarm connects to monitor the fire sprinkler system if water is flowing
Tamper – Fire Alarm connects to monitor if the water gets turned off – Supervisory
DACT Dialer /Communicator – IP – RADIO – CELLULAR – Tied to Panel for communication
Interface with access control or security system for specific purposes
Interface with access control will release maglocks upon fire alarm activation
Power Supplies to provide additional power for things like Horn/Strobes or smokes
Battery calculations and voltage line drop calculations
We don’t need to detail the technical aspects of battery calculations other than to explain that a licensed and trained Fire Alarm expert will calculate the current draw of each device to make sure that the power supplies provided will power all the devices and appliances and that there will be enough power even on long wire runs so that the last appliances or horn/strobes on the circuit will function.
Most of the time you would not install more than 8 horn/strobes on one circuit but there are several factors to this figure because if your wire runs are longer then you might only be able to install 4 or 5 and if you use high candela horn/strobes for a very large room then the figures change as well. This can change with the size of the wire and the size of the power supplies that you use.
When a contractor installs a 6amp power supply and there are 100 horn/strobes that draw 200mA each on the system that adds up to over 20amps so the system would not function, it would not pass a fire marshal test and you would be required to install additional power supplies to make it work.
You could install 8 Horn/Strobes on a 500 foot wire run using 14 gauge cable but you could not install 8 Horn/Strobes on a 1200 foot wire run because the appliances at the end would not have enough power to function. You can increase the size of the wire to 12 gauge but then many times the wire will not fit into the Horn/Strobe terminals and you have to make separate connections and reduce the wire making a trouble shooting problem for the future.
Depending on the calculations you may need larger batteries than 7amp so they may be 12 amp or 18 amp hour batteries to assure that the system will function for 5 min after a 24 hour AC power loss or in larger buildings it would be 15 min.
Elevator Recall
Smoke detectors in the elevator lobby when activated will send the elevator to a floor where there is no smoke. The programming normally sends the elevators to the first floor or if there is smoke on the first floor then the Fire Alarm System will send the elevator to the second floor or possibly the ground/basement floor depending on the building. Sometimes smoke detectors with built in relays are used and other times separate relays are used. Certain buildings may not be required to have a fire alarm system but may be required to have elevator recall in which case the panel could be labeled to say “Elevator recall system” instead of Fire Alarm System. The Fire Hat light in the elevator when lit indicates to anyone that may use the elevator that there is smoke in the elevator control room so it may not be safe to operate the elevator.
Elevator Monitoring
Elevator monitoring connects phone lines to each elevator phone where a live dispatcher will pick up the phone and talk to the person that is in trouble. JCI will need the caller ID to the elevator phone and JCI will issue an account number and also need a normal contract signed but the process is quite easy and quick to do. The Elevator contractor would only need to program the JCI 800 number into their equipment in order to make the change. Analog POTS phone lines are going away and being replaced with VOIP (Voice over IP) and we will provide a cellular unit because alarm systems and elevator phones do not work well with VOIP. VOIP lines do not have 24 hour UL listed battery backup so you should have POTS analog lines or cellular.
Communicators- DACT – Dialers – IP Internet – Radio – Cellular
Older communicators or dialers that worked on the phone lines may not work with digital lines and this could be causing problems on your fire alarm system when your phone lines changed to digital. These were known as DACT dialers and were used mostly with analog phone lines. It is very difficult to get analog lines even in new construction situations now. In fact even when you have copper and they tell you they are analog lines many times about 200 feet out the door they convert to digital.
In 2019 phone companies were given a three year period where they still needed to repair old analog copper phone lines in a building and now they no longer need to repair these lines after August of 2022 so Peak Alarm now installs Cellular Communicators rather than trying to get analog lines. VOIP phone lines typically are around 18 volts and Analog lines are about 54 volts. A phone company that tells you they will give you an analog line most of the time have this run through a digital phone system so the lines are not copper and not analog pots lines. They work fine for two people talking on the phone but they do not work well with 2 computers speaking to one another.
Now you can have your panel monitored using an IP Internet module when you have a static IP address although this is not the method we recommend since there are many aspects beyond our control that come into play and if the IP changes then your Fire Alarm or Security panel will stop communicating so JCI prefers Cellular. If there is a problem with your router or network equipment this could affect your signals and those devices are not on battery backup as per code as our cellular and radio systems are. There is an additional charge or radio or cellular although it is very reasonable price.
Cellular monitoring has two general types one which is normally used as a backup where if your phone line is cut it can send signals and then there is the high supervision type which send signals out every sixty minutes or over 700 times a month and that costs a bit more per month because it is sending signals so often.
Central Station
There are three UL listed Central Stations in Utah and the State Fire Marshal requires that Fire Alarm Systems be monitored over a UL listed Central Station.
UL listed is an expensive process that requires the Central Station receiving alarm signals to have backup generators, special security and backup receivers as well as a certain amount of dispatches on duty. It is a very difficult certification to obtain.
The dispatchers receive a signal and normally respond within seconds by either calling someone on the call list, the fire department, medical or the police depending on the alarm they receive.
Dispatchers cannot take an incoming call as an authorization unless you have the proper code words and account information. To change a call list you need to do it in writing. If you don’t want a dispatcher to call someone in the middle of the night then don’t put that person’s name on the call list. When a fire alarm has a low battery or other issues the dispatchers will call those on the call list no matter what time it is since it is a life safety issue.
Years ago the Police and Fire Stations used to receive signals directly from the stores or homes and would dispatch directly. This is no longer the case, all alarms, troubles and supervisory signals need to go through a Central Station first.
Customer Information Sheet
1. After signed paperwork is received and processed plan on 2-8 Weeks before the installation will take place. Normally equipment takes about 5 -7 business days to get here and we are normally booked out approximately 2-8 weeks depending on the size of the project. We can schedule small projects sooner on a first come first serve basis. (Longer if waiting on Fire Marshal approval. Some residential jobs are 1-2 weeks.
2. When switching over monitoring we will need an emergency call list, zone list, password and we will need to send test signals in on each point on the system.
3. Other services: Monthly monitoring fees vary based on what services you decide on. Monitoring/Guard/Cell/Radio/Elite/Web see attached sheet.
4. You can decide to add overtime on the projects under 8 hours and there is a possibility that we can put a rush on the project to get it done sooner although this also depends on equipment and the current schedule.
5. Another option is to pay for overnight shipping or two day shipping although with the process of paperwork this will get the equipment here but normally won’t speed up the 2-4 week lead time by more than a couple of days.
6. When you have questions about the contract don’t hesitate to ask. If you sign up for a repair agreement most labor and parts will be covered unless the equipment was damaged because of vandalism, an act of nature or an accident like an employee knocking a device off the wall with a forklift. Parts are warrantied for one year and labor is warrantied for 90 days.
7. You can enter into a service agreement with JCI
8. Call Larry Love 801 898 6003 for more information.
9. When you have changes done to your phone lines or change service providers this can affect the way your alarm system functions especially if they make any changes such as changing analog phone lines to digital phone lines or if they change how the RJ31X seizure boxes are wired. Analog lines often cost more than $100 per month.
Johnson Controls is not responsible for these items that we do not have control over. It is prudent to consider cellular monitoring in case the phone line is cut etc…
Mass Notification - Voice Evacuation
Code requires certain occupancies to have these special systems that can notify you using a voice message, strobes, tones and even tactile signals to alert occupants of any type of emergency. The voice message requirement is that it shall be understandable so speaker strobes have to be placed in a special configuration every so many feet to accomplish this. Many of the systems also have the ability to allow live messages as well. Some of the events that this system would be used for could be terrorist events, earthquake, person with a gun, fire, etc… The live message function would allow messages to be sent that may not be evacuation messages but it may be to stay where you are or move to a certain area. Other systems that are being integrated with these systems are text messaging and internet social media as well in order to notify an entire campus environment.
Fire Phone System
In very large building it is still required that a Fire Phone system be installed so firemen can plug phone headsets into jacks throughout the building to communicate. For the most part the Firemen use their radio headsets although this requirement is still part of the code. Larger buildings are required by code to provide special systems to make sure the emergency radios and phones work inside and around the buildings.
CCTV – Camera Systems – Analog / IP / DVRs / NVRs
This industry is changing very quickly and the new technology is very exciting. It is not prudent to continue using the older technology although you can still buy analog cameras and camera systems. It is quite difficult to get ahold of a VCR now so those are about out of circulation almost just like typewriters. DVRs are still very common and NVRs (Network video recorders) are another option. Currently you can purchase a hybrid DVR (digital video recorder) or NVR that will allow you to continue using your older analog cameras and add IP camera on in the future and as time goes on you can convert your analog cameras to IP cameras. We have converters that also allow you to continue using the same coax instead of having to change the wire. IP POE cameras (powered over the Ethernet) have some length limitations. When you have runs over 300 feet you will need power boosters or additional power supplies.
Currently we have entry level systems, midrange systems and enterprise camera systems that you can view remotely over your smart phone. This systems can be compared to purchasing a car. When you ask the car dealer for a car the price will depend on lots of factors including brand, features, warranty etc…the same applies to camera and security systems.
Verifocal lenses, vandal resistant housings, heater blowers are all options you could have for your cameras. Keep in mind that a megapixel camera will often be taking up several times the storage as your old analog camera so you will need to plan on a NVR that has enough capacity for your needs. Typically a quality system ends up costing $1000+ per camera or more which includes the recorder, cameras, power supplies, wire and installation.
Avoid getting cameras systems for your business from a big box store because “You get what you pay for” If you pay $50 dollars for a camera there is no way around it, you just bought a $50 dollar camera and that is very different than a quality camera. Many times cheap systems end up being very expensive.
Understand that viewing remote video over your phone will depend on your bandwidth at your home or office and the system you have. Using a static or none changing IP address for your NVR is a very wise move but many times cost and extra Port forwarding can be used however when changes are made you may have issues with the system and it may need to be reconfigured.
Coax – Cable – Low voltage wire - A brief overview -
Price of wire fluctuates with price of copper and oil. Price also depends on wire size
Coax – RG6 – Normally used for cable TV and should not be used for cameras
Coax – RG6 95% copper used for cameras with very long runs
Coax – RG59 much of the time with 18 gauge 2 conductor for power – cameras
CAT5 / CAT6 cable for IP Cameras – normally 328 foot limit per camera w/o extender
Fire wire normally RED normally 18 gauge for data loops and devices
Fire wire normally RED normally 14 gauge for Horn/Strobes (Shielded only for Speaker/Strobes)
FPL – Fire Rated Wire normally RED but can be ordered in white
FPLR Fire Rated Riser wire used for buildings taller than one story (holds it own weight in shaft)
FPLP Fire Rated Plenum wire meets req. of riser wire and puts off less toxic fumes when burning
Access Control cable bundled -18g2c for locks,22g6c reader,18g4c for motion,22g2c for contact
Security cable is normally 22g4 or 18g4c two conductor for the device and 2 for power
Wire gauge and conductors can vary depending on your specific project
For wire that will be on roofs or underground it is best to purchase wire that has the special UV rating and or burial rating so it will not be damaged as quickly by water or the sun.
Addressable data loop wire often needs to have a specific amount of twists per foot (12) for data transfer. Check the manufacturer wire recommendations.
Keep in mind that if a contractor needs to drill holes through walls, install long cable runs, rent a lift for high work, install special hangers for wire that these costs will add into your project. Deciding when you will require low voltage systems in conduit is a business decision since code does not require it other than in areas where the wire can be damaged by normally daily use. Conduit is expensive although it does protect the cabling.
Contractors should be licensed, insured, factory trained and have their individual state license as well for security systems. Our company will provide you with copies of all needed paperwork.
Access Control Systems
Access control systems control the locations and times people can enter specific doors. You can have doors on schedules to open or lock at certain times and you can have groups defined so managers can have 24 hour access or you can set it up so janitors can only enter certain doors on certain days within specific hour limitations. We also have badging systems for foto ID printing.
Access Control readers often are proximity readers where a card is placed near the reader in order to open the door. We also have readers that require a pin code as well to make the facility more security in case someone drops their card or loses it. We can install eye scanners or biometric fingerprint readers or even a vein scanner. Readers come in different sizes and some have the ability to read for longer ranges or be weather proof so we can help design a system to best fit your needs.
Reader, scanner or keypad
Controller (Can be wireless or on network or hardwired)
Request to exit motion when maglocks are used instead of electric door strikes
Sometimes an exit button is required in addition to the RTE motion
Electric locking hardware
Door Contact to monitor if the door is held open or blocked open.
Tie into Fire Alarm System for door release upon fire alarm.
We have entry level systems that more economical or midrange systems or enterprise systems that do not have limits on how many readers you can have installed and they can be controlled from one location and the cards programmed from a corporate office etc…
Security / Intrusion Systems
Intrusion systems normally have motion detectors, door and window contacts, glass break sensors and can be programmed to be silent alarms or have sirens and strobes activated. Often people do not utilize security systems to their full potential because you can also tie water sensors, liquid level sensors, gas sensors, high low digital temp sensors, humidity sensors and airflow sensors for server rooms all into your security system. You can control lighting, thermostats and many other building controls all from your security system.
Security systems can be very simple systems and very cost effective or they can be programmed to be very complex and more expensive.
We sell a double steel walled panel that cannot be pried open without destroying the wall and setting off a tamper that can be installed inside the can and the wall behind the can. We also have BMS contact that are balanced magnetic contacts so the system is much harder to defeat because a normal magnet will set the system into alarm if it is placed next to the contact or it will also alarm if the contact is pulled off the wall. Wireless systems have their place and they are getting better all the time although you should consult with a professional before making the decision on which type of system to have installed in your home or business. Motions – Tritech are better to avoid false alarms.
Certain panels can be programmed to arm and disarm different areas or partitions. You could have a strip mall with one panel controlling all 8 stores or more all with different keypads and codes activating independent of each other but all sending signals over the same communication set up.
Security Options not commonly understood
Late to open – This means you will get a call if your employees don’t disarm by a certain time. If they should have opened by 7am and they don’t open till 720am you would get notified.
Late to close – When your employees don’t arm the system up by a specific time you would get notified.
Early to open – You would get a notification if your building was disarmed before a specific time schedule.
Partitions – Although we already mentioned this keep in mind that you could have the office on a different partition from your working area or shop and those employees would not have access to the accounting area etc…Some people have a gun room or a wine cellar that is on a separate partition.
Web access
Security systems can also have lighting controls, thermostat controls, lock controls, garage door controls all programmed so that the customer can arm and disarm remotely, open or close the garage door, unlock doors, turn the heat up or down and turn the lights on or off using their smart phones.
Security Codes and understanding how they can/should be programmed
It is prudent to program in CODES that are not easy to guess, therefore avoid codes like 6969 or 3344 or 2468 or codes burglars try like birth year codes 1971 or 1980 etc…
Codes should be changed periodically and deleted when employees leave the company.
Installer code – This code is used to program the points and the system but normally does not have authority to arm or disarm the system.
Master code- This code is one you should not loose but keep locked up. Your Master code can be used to add more codes, change codes and delete codes.
User code – These are the normal codes for end users and employees.
When you intend on managing your own codes read the manual and get the training from your alarm contractor because you need to remember when programming codes that there are authority levels for each code, a name location for each code, areas to be programmed in for each code. Example: Betty may only have access to area 1 and 3 but not to areas 2 and 4 although Kyle may have access to all the areas and that needs to be entered when programming in codes. Often our customers would prefer that we do these changes for them and on many of our systems we can make these changes remotely.
Electrical Engineer information and why it is important to talk to them
For commercial systems it is wise to get an electrical engineer to design your system with plans and specifications. Then when bidders give you pricing they will all be bidding using the same guidelines otherwise you may not get consistent proposals. You can decide to go directly to an alarm contractor to get the design and the system installation although if you approach three or four companies your proposals will be all over the board if you do not have specifications with a clear scope of what work is to be done and by whom.
For Fire Alarm System often one of the requirements by the AHJ Fire Marshal is to have a PE stamp on your plans. PE is Professional Engineer. (Electrical Engineer stamp) Other times a NICET III stamp is acceptable.
Often cities will require that you submit drawings and submittals to the city inspector before the building permits are issued. It is prudent to verify in your city what is required so you can be prepared to get all of the steps completed and not hold up your construction or permits.
After your Electrical Engineer has done the plans and the specifications it is smart to go over the drawings and the scope of work to make sure it is clear and not under or over specified according to your budget. A good example is a project that we just bid out where the entire project came to 10,000 dollars but $3000 of the ten thousand was extra equipment that the Engineer required in the specifications. Verify with each bidder if they included that extra equipment because that may be why there is such a large price difference in the proposal. On this specific project the Engineer may have felt that since it was a shell and core system that they needed this equipment for the future which is fine as long as the property manager/owner understand that.
Code info such as NFPA 72, NFPA 70 (NEC) and Life safety 101 (ADA) & R710
NFPA 72 is the National Fire Alarm and Signaling Code
NFPA 70 is the National Electric Code – wire, conduit fill etc.. code
Life safety 101 ADA – Sometimes facilities require this code
R710 State of Utah Fire Code
IBC is the International building code
IFC is the International fire code (WHAT and WHERE required)
NFPA 72 has spacing requirements for smoke detectors, pull station and horn/strobes. It also has mounting heights and requirements for communications and operations. NFPA 72 also has the testing requirements listed. (HOW)
Example: NFPA 72 current edition and current adopted edition no longer require smoke detectors at the fire alarm panel location on a fully sprinkled building although R710 Utah code still requires smokes at the Fire Panel so it will communicate before the panel burns up in the event of a fire at the panel location.
Life Safety 101 can require horn/strobes every 50 feet in the hallways rather than every 100 feet like the NFPA 72 code so if your occupancy and facility requires this code to be met adjustments will need to be made to appliance, devices and spacing.
Having a knowledge of these codes is very important especially when installing fire alarm and access control systems.
Maintenance note – extend the life of your system
Having your smoke detectors cleaned out periodically is one way to increase the life span of your detectors and system. Many times just blowing them out is not going to work as well as taking them apart and cleaning out the inner chambers. If your detectors are over ten years old in a residential environment it is recommended that you purchase new ones. When you don’t maintain your fire and security systems you can end up with more false alarms and costly service at a later date.
Utah code requires that your Fire Alarm System be tested at least once a year. Your insurance company may require additional tests.
Batteries normally last from 3 to 5 years. The other day a gentleman told me he had a set of batteries last 12 years. Most likely they did not last the full 12 years because when you do a load test with a special battery tester you will see that they may pass the voltage test but fail the load test. This means if you lose power the batteries most likely will not continue to function or run the system as they should. When you replace the batteries do not mix up the red and black wires as you can burn out the panel equipment which can be very expensive. It may be best to call a technician to do this routine maintenance for you.
When you replace the batteries be sure to tag the battery with the date that you changed them out. Also if you purchase your own batteries check the manufacture date because if you purchase them from a store that does not rotate their batteries on a constant basis you may have purchased a battery that was a year or two old to start with. The manufacture date is stamped on the top of the battery.
Supplementary Information:
The information provided in this packet will help you obtain much
of the knowledge that you will need to be able to make sound
decisions regarding these systems. Please remember to consult
with the local AHJ or Fire Marshall for his or her final decisions
on code requirements. Keep in mind that this information is no
substitute for an Electrical Engineer or design consultant. The
expertise that security contractors gain from years of experience is
a very valuable asset in the design process and most contractors
charge for these services.
It has not been very long ago that you could have your electrician
install a system and then you could forget about it. With the new codes,
requirements & liability associated with these systems it is best if you
hire a Fire Alarm Contractor that has experience in this field and is
regularly engaged in the installation of such systems.
Some Electrical Contractors have a special division that focuses on these low voltage systems and they do a very professional job.
These systems need to be tested and cleaned regularly.
If you intend on remodeling or building a new facility the assumption is that the plans that are drawn up by the engineer are reviewed by the Fire Marshall in plan review.
This assumption is incorrect. The Fire Alarm plan should be submitted
to the Fire Marshall to be approved and this is separate from plan
review. Working in conjunction with the AHJ or Fire Marshall is a
good idea and will save you headaches in the long run. Many companies will
try and do the minimum required by code just to get by.
Other companies because of insurance requirements have additional systems installed.
When Johnson Controls designs a system it is done to code. Designing your
system to surpass code is very advantageous, not only for liability sake
but for peace of mind. Knowing that your maintenance department and
the authorities will be called automatically in case of fire, flood or
security breach assures that the proper action can be taken to avoid
problems that can be costly to the company and it also shows the public
that your company did everything in its power to avoid any accidents
or incidents. When I refer to surpassing code requirements it would include such sensors as high and low digital temperature sensors, humidity and airflow sensors for server rooms, remote video to verify alarms, additional protection such as flame detection for specific circumstances and so on.
Many fire alarm contractors are leery to give out unit pricing. Each
Project is different in the fact that some projects may require that
Trenching between buildings be done or drilling through walls to run
Wire or extremely long wire runs may be needed. With all the factors
taken into consideration prices will vary depending upon how busy a
contractor may be, the price of copper (wire) and the labor that the
individual job may take. Many times a customer may require a fixed
bid. A time and material bid will in most cases save the end user quite
a bit. Fixed bids take into consideration several contingencies that may
come up. Prices on new construction work will be more consistent
than prices on remodels. Johnson Controls is not always the low bidder, however
JCI is very professional and will do the job right the first time.
Johnson Control has a saying in the office: "Your Protection is our profession".
General Terms : (Just a few of the Alarm terms you may need to know)
Not in alphabetical order
FACP – Fire Alarm Control Panel
Voice evac or mass notification – System that notifies occupants with special instructions for different emergency situations. Speaker strobes are installed and you need to be able to understand the instructions.
Zoned – A wire goes to each point such as smokes, motions and then back to the panel. (Homeruns) This takes more labor and more wire although it can be more secure.
Addressable– One long piece of wire has all the devices on it reporting individually whether it be a security or fire alarm system. Normally the modules cost anywhere from $35 dollars each up to $85 each depending on the system so you need to decide if you save enough money in conduit, wire and labor when installing an addressable loop. The point is normally around 24 points where it becomes cost effective to install an addressable system.
Addressable module MM– A small box that will tell the panel the exact location of the device such as a door, smoke detector etc…
Duct Detector DD- A smoke detector that detects smoke in the duct work that has relays to shut down the RTU. If the belt burns out and cases smoke you can have the duct detect shut down the RTU before more damage is done. (Just one of the purposes) RTU= Roof Top Unit (Air handler)
NFPA 72 – National Fire Alarm Code
Manual Pull box or Pull Station – That is the small red box you pull if there is a fire
PIV valve – This is a shut of valve that can shut off the sprinkler water to the fire alarm sprinkler. Otherwise known as POST INDICATOR VALVE
Horn/Strobe – These are the noisy red or white boxes on the wall that flash and make noise.
RTE – Request to exit motion or some refer to this as request to enter if they use the REX as a request to exit motion. This motion can release the magnetic lock holding the door and you could have a button as well.
Proximity card reader – These little boxes are what you put your access card up against so the system will open the door. These door systems vary in price but they have special electronic locks, the reader, the hold open door contact and a controller. These normally cost from $1,500 to $2,800 dollars depending on the brand name of equipment and the location in the building.
Larry Love (801) 898 6003 Larry.Love@JCI.com
System Type
Phone Burglar
Cellular Burglar
Phone line Fire Alarm
Cellular Fire Alarm
Install cost will vary depending on the plan you pick
Cell or Radio monthly fee will vary if it is a fire alarm system or security or combined system. If there are areas where we dispatch to different call lists or addresses we can put together a specialized plan for your situation. High supervision cellular for fire sends several signals every day whereas security cells don’t.
NOTE ON PHONELINES: If you are paying for monitoring and paying for analog phone lines you may be paying too much. If you can cancel your phone line and use a cellular or radio it can save you quite a bit of money in the long run. Analog phone lines are becoming a thing of the past so plan on having your systems communicate using CELLULAR technology.
FIRE ALARM INSPECTIONS can be added to your services and JCI will schedule the required annual inspection once a year. The cost of this is determined by the amount of points on your system. When you get Johnson Controls a list of the points on the system we can price out the inspections for you. Utah has adopted NFPA 72 and IFC (International Fire Code) and annual fire alarm inspections are required by law and many times additional inspections are required by your insurance companies.
We can get you pricing on the larger facilities once we have a complete count of the devices and appliances.
Pricing for testing and takeovers depend on the amount of zones/points and what testing needs to be done to bring the system online.
** Some alarm systems are so old that they cannot upgrade without changing the main panel, in which case we would need to know the exact model, brand and version of the system, how many devices, how many keypads and it is best to do a site visit before quoting pricing. Larry can come out to your facility or home at no charge to do this evaluation. If your Fire Alarm system can communicate using contact ID we can tie a new cellular unit on it, so it will be able to communicate. Fire Alarm High Supervision cellular units that send several signals per day.
*** Currently we do not offer remote arm and disarm services when using a radio to communicate. Often it is best to switch to cellular if you have an AES Radio because of coverage issues.
Note that GE Interlogix has gone out of business in 2019 and you could get parts in 2020 but in 2021 you can no longer purchase parts other than methods such as Ebay and there is no warranty when purchasing over the websites such as these so Peak Alarm does not do GE Interlogix takeovers although we can install new equipment and use the existing wiring.
Additional services such as schedules, openings and closings, UL2050 certificate are offered by Johnson Controls and pricing is available upon request.
On large or complicated sites a site evaluation will need to be done in order to price out the monitoring switch, inspections, repairs etc. When there are multiple power supply locations, older equipment, duct detectors, dampers, elevator recall and other such items the testing will need to be evaluated first.
ABOUT JOHNSON CONTROLS FIRE PROTECTION:
1. In business 100+ years
2. Highly Trained Staff
3. UL listed Central Station
4. Offices servicing all 50 states
5. JCI has the ability to do very complex fire alarm systems. We installed the fire alarm system at the Salt Lake Airport.
FINAL NOTE:
This short report is not a substitute for working with an alarm professional who has experience and certifications required to install and program these systems. The purpose of the report is to give you a better knowledge of general alarm systems so you can better work with the alarm contractors. When you note any errors please contact larry.Love@JCI.com and he will make corrections to the report.
Please let us know if this report has been helpful to you. Larry Love 801 898 6003